CT-4008Tn-5V6A-S1
CT-4008Tn-5V6A-S1 is Neware one of the best selling models which is widely used in cell manufactuers,
universities and labs worldwide. It's great for testing different sizes of cylindrical, pouch and coin cells.
Neware has launched new CT-4008Tn-5V6A-S1 with three output current ranges which can improve the
testing accuracy based on varying charging/discharging current. Each CT-4008Tn-5V6A-S1 has 8 channels,
and each channel is indepent. Working with Neware powerful software, it can be your best partner in the
daily test.
Specs Keep improving and lead the market.

500ms
Min.Pulse Width

≤1ms
Response Time

0.05%
Accuracy

DCIR Test

3 Range

10Hz/100Hz
Data Acquisition Frequency
CT-4008Tn-5V6A-S1 with Three Output Current Ranges
To meet the various requirements adopted in advanced battery research,
our equipments can automatically switch the current range in accordance
with user settings to maintain consistent accuracy, and can be fitted
with additional hardware to provide a number of optional features
and capabilities. The model CT-4008Tn-5V6A-S1 can be configured
with multi-current range channels, which have a current control
range of 0.5mA to 0.1A, 0.1A to 3A, 3A to 6A as standard.
The accuracy for current and voltage on these channels is ±0.05% FS.

Discover the difference between 5V6A and 5V12A
Neware 5V6A and 5V12A test equipment are almost same in their appearence, we can distinguish them from aerial insertion and ventilation design.

5V6A uses one fan, but 5V12A uses two.

Air intake on the right or left side
The inventive heat-radiating system is practical and feasible and can
increase heat-radiating efficiency and space utilizaion rate. Each
CT-4008-5V6A supports from one to eight test channels, depend
on the application.Each test channel is operated independently.
This allows different tests to be performed on different test channels
simultaneously, with tests being started independently, or in a block.
Square Air Outlet
Compared with 5V6A, 5V12A uses two square fans for dissipating heat.
Industrial design is delicate.
CT-4008Tn-5V6A-S1 battery testing system combined one middle machine, which can work with up to 10 sets of 5V6A equipments. What's more, you can use one gantry to DIY a new equipment. The most surprising thing is that it can save much more floor space.

Integrated operation and collaborative work through BTS upper computer control system
NEWARE battery charge and discharge test system realizes integrated
operation and collaborative work through BTS upper computer control
system, so as to maximize the battery characteristics and functions.
Software
Essential components

dQ/dV
dQ/dV differential capacity curve: the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve, and different peaks represent different electrochemical reactions.

Conditions Switches
Battery testing steps need to be estimated for several conditions according to different operations during testing applications; Conditions switches meet requirements for multi-exits programming types. “And””or” logic operation, “≥”, ”≤”, ”=” comparatively calculate; Time duration ”t”, can achieve control requirements for special testing. Every step supports 5 condition switches; Support multi-exits, go to any steps, achieve more flexible process control.

Segment-Record Conditions
Data record settings for voltage, current and time are supported; 3 segment-record conditions can be set for each step; Every segment can be set: ΔT, ΔV and ΔI .

Control peripheral equipment by communication
BTS Server come true the peripheral equipment (Battery tester & Automation) communication control via switch.

EDLC Testing
The unit of Q is Coulomb, 1 Coulomb = 1A * 1s = 1As; 1Ah = 3600 As(Amp Second); Work voltage U = Charge upper limited voltage - Discharge bottom limited voltage; Working voltage can be set and the EDLC coulomb could be calculated automatically by the software.
Application
Good news for lithium battery manufacturers
Polymer Pouch Cell
Using polymer clamps to test, such as 6545 polymer clamp.

Cylindrical Cell
The upper and lower clamps of Neware 5V6A and 5V12A tester
can move up and down accurately according to the scale
marked on the left and right sides. The cylinder battery is tested
between the upper and lower clamps.

Supercapacitor
Using polymer clamps to test, such as 6545 polymer clamp.

Customer Site

A large number of 5V6A testing equipments are running at customer' sites.