4 ranges, wide dynamic range, high speed sampling and high accuracy.
NEWARE-Battery Tester
CT-9000 Battery Testing System
| Voltage & Current | Range / Current | |||
| Range 1 | Range 2 | Range 3 | Range 4 | |
| 5V6A |
0.1μA ~ 180μA |
180μA ~ 6mA | 6mA ~ 180mA | 180mA ~ 6A |
| 5V12A | 0.12mA ~ 12mA | 12mA ~ 120mA | 120mA ~ 1200mA | 1200mA ~ 12A |
| 5V15A | 0.15mA ~ 15mA | 15mA ~ 150mA | 150mA ~ 1500mA | 1500mA ~ 15A |
*Other models can be customized according to voltage and current requirements.

Tiny currents can be lightly captured.
Seizing the fleeting changes.
Distinguishing within millimeters.

Voltage & Current Accuracy
±0.02% F.S.

Recording Frequency
1000Hz

Resolution AD
16bit

Current Response Time
≤100μs

Minimum Pulse Width
400μs

Off-Line Test
1GB
High sampling accuracy, fast response time, high control accuracy and wide measurement range.

All-around product tour.




4-Range, precision to the utmost.
4 current ranges from 0.1μA ~ 150μA, 150μA ~ 5mA, 5mA ~
150mA, 150mA ~ 5A can be selected respectively to realize the
controllable accuracy of small current in small range.

Safety protection
keeps machines
working longer.
● Discharge Data Protection
● Offline Testing Function
● Voltage Upper Limit Setting
● Voltage Lower Limit Setting
● Current Upper Limit Setting
● Current Lower Limit Setting
● Capacity Upper Limit Setting
● Voltage Fluctuation Protection
● Current Fluctuation Protection

High precision sampling.
Perceive every small fluctuation
Up to 1000Hz data recording frequency Compared to other
modules of NEWARE testers, the CT-9000 series has a higher
recording frequency up to 1000Hz. The IEC standard DCIR
function of the CT-9000 is also based on the high frequency
data set, allowing more DCIR values to be obtained in the same
time range.

Extensive peripheral devices.
Create a multi-dimensional testing environment.
Integrated peripheral devices such as Auxiliary Voltage, Auxiliary
Temperature, and Environmental TestChambers for
comprehensive testing and evaluation, providing multi-
dimensional and quantifiable support for battery mass
production testing.

A multitude of functionalities.
Accomplishing the testing of new species.

Pulse simulation test

Cycle life test

Rate Charging / Discharging
Test

DCIR test

dQ/dV differential capacity
curve

Support Differential Capacity Curve Test, designed for battery research in Universities, Research Institutes and etc.

Powerful programmability.
Meet diverse testing needs.
The software is fully functional, covering a variety of work-step settings, recording, and data storage to meet a wide range of testing needs.

400μs pulse width
The pulse test supports the setting of a minimum pulse width of 400μs, which can be used to check the performance of the battery pack under rapidly changing current and power.

Simulation
Simulation test support. Simulate the actual battery pack testing environment to verify the battery pack performance under real using. It supports loading maximum 100W rows of changing data.

Discharge to 0V *
Forced discharge of the battery pack to 0V, suitable for various safety tests, destructive tests and other tests of the battery pack.
*This function is optional.

Conditions switches
Battery test steps need to be estimated for multiple conditions according to different operations during test applications; condition switches meet requirements for multi-exit programming types. Each step supports 5 condition switches; support multi-exits, go to any steps, achieve more flexible process control.

Technical Specifications
| Equipment name | CT-9008-5V5A-SMB |
|---|---|
| Voltage | |
| Output range / channel | Charge:0V ~ 5V Discharge:0V ~ 5V |
| Minimum discharge voltage | 0V |
| Accuracy | ± 0.02% of F.S. / range |
| Stability | 0.005% of F.S. |
| Current | |
| Output range / channel | Range1: 0.1μA ~ 150μA Range2: 150μA ~ 5mA Range3: 5mA ~ 150mA Range4: 150mA ~ 5A |
| Accuracy | ± 0.02% of F.S. Range1: ±30nA Range2: ±1μA Range3: ±30μA Range4: ±1mA |
| Stability | ±0.005% of F.S. |
| Power | |
| Output power / channel | 25W |
| Stability | ± 0.02% of F.S. |
| Time | |
| Current response time | ≤ 100μS (10% to 90% or 90% to 10%) |
| Working step time | ≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms) |